Measurement Chamber Addon
for Deposition Cluster Tools

Higher Thin-film and substrate quality through fast and precise Near-process Measurement
based on non-contact eddy current technology.

Record a Line Profile of the wafer and thin-film.

Introduction

The EddyCus® inline MCM is a metrologoy chamber module for wafer deposition cluster  tools. It consists of two non-contact eddy current Semi-Vac Sensors operating in transmission mode with only the tip is inside the vacuum and the chamber with SEMI conform connection to the handling chamber.

It is dedicated to measure the sheet resistance [Ohm/sq] or metal layer thickness [nm, µm] of an applied layer or the resistivity [mOhm·cm] of the substrate. 

The software records a line profile that provides an insight into the quality of the coating or substrate. Different designs for common coating machines such as Endura available.

The interconnection module is typically used for:

  • Upgrade of existing deposition systems with measurement capabilities
  • Enhanced instant quality control
  • Line profile of sheet resistance, metal layer thickness and resistivity

Sensor Capabilities

  • Sheet Resistance [0.001 – 1,000  Ohm/sq]
  • Metal Layer Thickness [1 nm – 2 mm]
  • Resistivity [in accordance with sheet resistance]

Supported Substrates

Wafer, Glass, etc. with 150 / 200 / 300 mm diameter

Optional Temperature Sensor

Features and Benefits

Measurement on
Process Wafers

LIVE

Optimize Process Parameters on the Fly

Quality

Improve Device Performance

Lifeme

Early Sorting Out of Misprocessed, Inhomogeneous Wafers

Reduce System Downtime

Higher Wafer Throughput

$

Reduce Coating Cost per Wafer

Data

Process Qualification Measurement

Interfaces

  • OpenAPI / HTTP (Rest API) – integrable with ASUconnect
  • Anybus interface modules
    • UDP
    • PROFINET
    • Modbus/TCP (on request)
    • EtherCAT (future feature)
    • Ethernet/IP (future feature)
  • IO module
    • 2x trigger channels (2 axis) + 1x reset per channel
    • Options with 5 V DC or 24 V DC input
    • 500 Hz input (3000 Hz on request)
    • Optional: Trigger output 4..20 mA and 0..10 V

Video of the EddyCus® inline MCM

The video gives you an impression of how the measurement chamber module works.

Image Gallery

Data Table for EddyCus® inline MCM

System Features

Measurement technology Non-contact high frequency eddy current sensor
Place of measurement In-vacuo in dedicated metrology chamber
Substrates Wafer, glass, etc.
Measurement gap size 5 – 50 mm (depending on wafer handler)
Substrate sizes 150 / 200 / 300 mm (different sizes of MCM are available)
Conductive layers Metals, alloys and other conductive layers
Measurement types Sheet resistance, metal thickness, resistivity, wafer temperature
Environment In-vacuo, wafer temperature up to 500 °C / 932 °F
Sample rate 1 / 10 / 50 / 100 / 1,000 measurements per second
Hardware trigger 5 / 12 / 24 V

Measurement Capabilities

Sheet Resistance Measurement
Sheet resistance measurement range 0.001 – 1,000 Ohm/sq
Metal Layer Thickness Measurement
Metal layer thickness range
(e.g. Cu, Al, Ag, Au, Ni, Ti, Ta, Pt, W)
1 nm – 2 mm (in accordance with sheet resistance)
Metal layer thickness measurement by conversion or direct calibration (both software supported)
Resistivity Measurement
Resistivity measurement range Resistivity measurement by conversion or direct calibration (both software supported)
Emissivity Measurement
Emissivity measurement range Emissivity measurement by conversion

Frequently Asked Questions

Sheet resistance, metal layer thickness, resistivity,